Internal Vibration
- Internal vibration is required. External vibration is not sufficient and is not code compliant.
- Use a low impact pencil vibrator with a ¾ to 1” head and a ¾ to 1.5 HP motor.
- Either gas or electric is acceptable.
- The recommended technique is fast in, slow out.